Size of cup affects the anterior capsular distance in total hip arthroplasty, as measured with ultrasound

pdf
Số trang Size of cup affects the anterior capsular distance in total hip arthroplasty, as measured with ultrasound 3 Cỡ tệp Size of cup affects the anterior capsular distance in total hip arthroplasty, as measured with ultrasound 464 KB Lượt tải Size of cup affects the anterior capsular distance in total hip arthroplasty, as measured with ultrasound 0 Lượt đọc Size of cup affects the anterior capsular distance in total hip arthroplasty, as measured with ultrasound 44
Đánh giá Size of cup affects the anterior capsular distance in total hip arthroplasty, as measured with ultrasound
4.4 ( 17 lượt)
Nhấn vào bên dưới để tải tài liệu
Để tải xuống xem đầy đủ hãy nhấn vào bên trên
Chủ đề liên quan

Nội dung

Tarasevicius et al. BMC Musculoskeletal Disorders 2014, 15:23 http://www.biomedcentral.com/1471-2474/15/23 RESEARCH ARTICLE Open Access Size of cup affects the anterior capsular distance in total hip arthroplasty, as measured with ultrasound Sarunas Tarasevicius1,2*, Valdemaras Loiba1, Justinas Stucinskas1, Otto Robertsson2 and Hans Wingstrand2 Abstract Background: Previously was found that sonography is a reliable method to measure a capsular distance in total hip arthroplasty hips. The aim of our current study was to investigate the relation between the implanted size of the cup and the anterior capsular distance, as measured with ultrasound one year after THA. Methods: 50 osteoarthritis (OA) patients operated on with total hip arthroplasty one year before were included in the study and the anterior capsular distance was measured sonographically. Patients were grouped with respect to cup size. The correlation between the implanted cup size and capsular distance was determined. Results: The mean capsular distance in the whole group was 1.37 (SD 0.19) cm. The mean capsular distance in the group with small cups was 1.27 (SD 0.13) cm, in large cups it was 1.45 (SD 0.20) cm, p = 0.02. Spearman correlation analysis showed a statistically significant correlation between a greater capsular distance and the larger size of the cup (r = 0.5, p < 0.0001). Conclusion: The greater capsular distance in successful THA hips is affected by cup size. We propose that this should be considered when evaluating sonography of the anterior capsular distance after THA. Keywords: Sonography, Cup size, Capsular distance, THA Background Ultrasonography (US) is a valuable tool for diagnosing capsular distension in the hip joint and has been used for diagnosing synovitis, infection and hemarthrosis [1-3]. It has also been used in research, e.g. to demonstrate a correlation between radiographic signs of wear and loosening and increased capsular distance in cemented total hip arthroplasty (THA) [4-6]. Thus, measuring the capsular distance after THA may provide useful clinical information necessary for diagnostic assessment. Previously we investigated the reliability of US in vitro to measure the capsular distance in a plastic model. Subsequently, we used US measurements from 22 THA patients, and by 3 different examiners, to calculate intra- and interobserver agreements [7]. We concluded that ultrasonography is a reliable method for measuring anterior * Correspondence: sarunas.tarasevicius@med.lu.se 1 Department of Orthopedics, Lund University Hospital, Getingevagen 4, Lund 22185, Sweden 2 Departments of Orthopedics, Lithuanian University of Health Sciences, Eiveniu 2, Kaunas LT-50009, Lithuania capsular distance in THA, especially if performed by an experienced examiner. However, there is a lack of information whether the US measurements may be affected by factors such as the size of the implanted components. The aim of our study was to analyze the relation between the implanted size of the cup and the anterior capsular distance, as measured with US in patients one year after successful THA. Methods We examined 50 primary non inflammatory osteoarthritis (OA) patients operated on with THA during the course of 6 months that one year after surgery had no or minimal pain, and that were not using pain relieving drugs. All the patients had received the same type of standard offset stem (DePuy, C-stem) with a 28 mm femoral head together with an all-poly cemented cup (DePuy, Ultima). All the patients had been operated on using posterior approach leaving the anterior capsule intact. The patients were divided into two groups; Group © 2014 Tarasevicius et al.; licensee BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Tarasevicius et al. BMC Musculoskeletal Disorders 2014, 15:23 http://www.biomedcentral.com/1471-2474/15/23 Page 2 of 3 A consisting of those with 44, 46 and 48 mm outer diameter cups and group B with 54, 56 and 58 mm cups. 12–13 months after their surgery a US examination was performed. A portable Sonosite 180 L38 (Sonosite) apparatus with 5–10 Mhz linear transducer was used for all examinations. All the measurements were performed by one researcher with the patient supine in a sagittal plane, from the anterior aspect of the hip along the axis of the femoral neck. The anterior capsular distance was defined as the distance between the metallic echo from the mid part of the anterior surface of the prosthetic femoral neck perpendicular to the echo from the inner layer of the anterior capsule (Figures 1 and 2). The primary effect variable, used for power calculation analysis, was the capsular distance. With an assumption of a difference in means of 3 mm, and an SD (standard deviation) of 3 mm for both groups, and aiming at a power of 0.80 and a risk of 0.05 for type-1 error, 16 patients were required in each group. Age, capsular distance, were compared between groups using the Mann– Whitney U test The Spearman correlation (r) was used to calculate the correlation between variables. A p-value of < 0.05 was considered significant. SPSS software was used for the calculations. The study was approved by the ethical committee of the Lithuanian University of Health Sciences hospital, Kaunas Clinics (BE-2-19). Informed consent was obtained from each subject in writing before study and only patients older than 18 years were included. Figure 2 Sonographic measurement of the capsular distance in THA. AC - echo from the anterior surface of the anterior hip joint capsule. FN - echo from the anterior surface of the prosthetic femoral neck. FH – echo from the anterior surface of the prosthetic femoral head. d - represents the distance between anterior capsule and prosthetic femoral neck. Results and discussion Group A with the smaller cups included 22 patients of which 2 were males, while group B included 28 patients of which 23 were males (Table 1). The mean capsular distance for the whole group was 1.37 (SD 0.19) cm. The mean capsular distance in group Figure 1 Schematic drawing showing sonographic findings in THA patients. FH: prosthetic femoral head; FN: prosthetic femoral neck; AC: anterior capsule; d is the distance between the anterior capsule and the prosthetic femoral neck; 1 is the echo from the prosthetic femoral head (FH); 2 is the echo from the prosthetic femoral head (FN); 3 is the echo from the prosthetic collar (not always present). Table 1 Patients related data, in small and large THA cup groups (n = 50) Variables Group A, n = 22 Group B, n = 28 p-value Age 73 (SD 8) 66 (SD 12) 0.02 Gender M-2, F-20 M-23, F-5 <0.001 Tarasevicius et al. BMC Musculoskeletal Disorders 2014, 15:23 http://www.biomedcentral.com/1471-2474/15/23 A was 1.27 (SD 0.13) cm and varied from 1.02 – 1.45 cm, in group B it was 1.45 (SD 0.20) cm and varied from 1.16 – 2.16 cm, p = 0.02. Mean capsular distance for males was 1.46 (SD 0.20) cm, for females 1.28 (SD 0.14) cm, p = 0.001. Spearman correlation analysis showed a statistically significant correlation between the greater capsular distance and the larger size of the cup (r = 0.5, p < 0.0001). No significant correlation was observed between stem size and capsular distance (p = 0.3). In a healthy hip there is no measurable distance between the femoral neck and the inner layer of the anterior capsule as the amount of joint fluid is minimal [8]. However, due to the relatively narrow femoral neck in THA there will be room between the neck and an intact anterior capsule immediately after surgery which does not fill up completely with scar tissue, at least not in during the course of one year, as shown by this and previous studies on well-functioning hips [6]. We established that the anterior capsular distance as measured with US at 1 year after the surgery is affected by the size of the cup, but not by the size of the femoral stem. Our findings are explained by the geometry of the hip since the proximal part of the capsule is attached to the borders and the roof of the acetabulum, while the distal part of the capsule is attached to the intertrochanteric region of the femur. An increase in the acetabular cup size increases the radius of the capsular attachment which in turn increases the distance between the metal femoral neck and the capsule in all directions. Also it was reported that greater sonographically measured “capsular distance” is correlated to increased linear and volumetric wear in radiographically stable THA hips [6] and it is in concordance with other literature report that acetabular cup size may lead to the higher risk of the implant failure [9]. We wound a mean capsular distance of 1.37 cm for the whole group, which is in concordance with our previous findings where we similarly investigated THA patients one year postoperatively and found mean capsular distance of 1.34. Thus, according our studies we define the normal values of capsular distance but taking into account the cup size. Conclusion We conclude that the greater capsular distance in successful THA hips is affected by cup size and propose that this should be considered when evaluating sonography of the the anterior capsular distance after THA. Page 3 of 3 Authors’ contributions ST: data collection, compilation and analysis, writing manuscript, VL: data collection, editing manuscript, JS: data collection, editing manuscript, OR: statistical analysis, editing manuscript, HW: organizing study, editing manuscript. All authors read and approved the final manuscript. Acknowledgements This study was supported by: Lunds sjukvårdsdistrikt/Region Skåne, the Swedish Research Council (Project 73X-09509), the Swedish National Board of Health and Welfare and the Medical Faculty, University of Lund, Sweden. Received: 30 August 2013 Accepted: 17 January 2014 Published: 20 January 2014 References 1. Földes K, Gaal M, Balint P, Nemenyi K, Kiss C, Balint G, Buchanan W: Ultrasonography after hip arthroplasty. Skeletal Radiol 1992, 21(5):297–299. 2. van Holsbeeck MT, Eyler WR, Sherman LS, Lombardi TL, Mezger E, Verner JJ, Schurman JR, Jonsson K: Detection of infection in loosened hip prostheses: efficacy of sonography. AJR Am J Roentgenol 1994, 163(2):381–384. 3. Long SS, Surrey D, Nazarian LN: Common sonographic findings in the painful hip after hip arthroplasty. J Ultrasound Med 2012, 31(2):301–312. 4. Kesteris U, Jonsson K, Robertsson O, et al: Polyethylene wear and synovitis in total hip arthroplasty: A sonographic study of 48 hips. J Arthroplasty 1999, 14(2):138–143. 5. Robertsson O, Wingstrand H, Kesteris U, Jonsson K, Onnerfalt R: Intracapsular pressure and loosening of hip prostheses. Preoperative measurements in 18 hips. Acta Orthop Scand 1997, 68(3):231–234. 6. Tarasevicius S, Robertsson O, Kesteris U, Kalesinskas RJ, Wingstrand H: Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty: a sonographic and radiographic study of 39 patients. Acta Orthop 2008, 79(4):489–493. 7. Tarasevicius S, Skikas L, Mitraite D, Torii Y, Kesteris U, Wingstrand H: Sonography in total hip arthroplasty. Ultraschall Med 2007, 28(5):475–478. 8. Wingstrand H, Wingstrand A: Biomechanics of the hip joint capsule - a mathematical model and clinical implications. Clin Biomech (Bristol, Avon) 1997, 12(5):273–280. 9. Hrubina M, Behounek J, Skotak M: Mid-term results of cementless ultima cups in primary total hip replacements. Acta Chir Orthop Traumatol Cech 2008, 75(3):205–211. doi:10.1186/1471-2474-15-23 Cite this article as: Tarasevicius et al.: Size of cup affects the anterior capsular distance in total hip arthroplasty, as measured with ultrasound. BMC Musculoskeletal Disorders 2014 15:23. Submit your next manuscript to BioMed Central and take full advantage of: • Convenient online submission • Thorough peer review • No space constraints or color figure charges Abbreviations OA: Osteoarthritis; US: Ultrasonography; THA: Total hip arthroplasty; SD: Standard deviation. Competing interests The authors declare that they have no competing interests. • Immediate publication on acceptance • Inclusion in PubMed, CAS, Scopus and Google Scholar • Research which is freely available for redistribution Submit your manuscript at www.biomedcentral.com/submit
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.