Getting started: SITOP UPS1600 under STEP 7-V13

pdf
Số trang Getting started: SITOP UPS1600 under STEP 7-V13 38 Cỡ tệp Getting started: SITOP UPS1600 under STEP 7-V13 2 MB Lượt tải Getting started: SITOP UPS1600 under STEP 7-V13 0 Lượt đọc Getting started: SITOP UPS1600 under STEP 7-V13 0
Đánh giá Getting started: SITOP UPS1600 under STEP 7-V13
4.1 ( 14 lượt)
Nhấn vào bên dưới để tải tài liệu
Đang xem trước 10 trên tổng 38 trang, để tải xuống xem đầy đủ hãy nhấn vào bên trên
Chủ đề liên quan

Nội dung

SITOP UPS1600 under STEP 7 V13 1 ___________________ Introduction 2 ___________________ Safety notes 3 ___________________ Description 4 ___________________ Assigning the IP address SITOP UPS1600 under STEP 7 V13 Getting Started 06/2014 Installing and configuring the SITOP UPS1600 in STEP 7 V13 5 ___________ Parameterizing the SITOP ___________________ 6 UPS1600 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY Ⓟ 06/2014 Subject to change Copyright © Siemens AG . All rights reserved Table of contents 1 Introduction................................................................................................................................... 5 1.1 Purpose of this document ......................................................................................................... 5 1.2 Technical support ..................................................................................................................... 5 1.3 Additional documentation ......................................................................................................... 6 2 Safety notes ................................................................................................................................. 7 3 Description ................................................................................................................................... 9 3.1 System overview ...................................................................................................................... 9 4 Assigning the IP address .............................................................................................................. 11 5 Installing and configuring the SITOP UPS1600 in STEP 7 V13 ......................................................... 17 6 Parameterizing the SITOP UPS1600 ............................................................................................. 25 6.1 Buffering an S7 IO controller, including the I/O when the power fails ....................................... 25 6.2 Switching off the UPS when the power fails by a user program ............................................... 29 SITOP UPS1600 under STEP 7 V13 Getting Started, 06/2014 3 Introduction 1.1 1 Purpose of this document This Getting Started guides you through configuring the UPS1600 under STEP 7 V13 for the following two tasks: ● Buffering the S7 IO controller, including the I/O when the power fails ● Switching off the UPS when the power fails by the user program Basic knowledge required The following are required to understand the Getting Started: ● Knowledgeable about using personal computers with the Windows operating system ● Knowledgeable about how to configure an uninterruptible power supply using the UPS1600, including the S7 IO controller and connected battery modules ● Creating and editing projects under STEP 7 V13 in the TIA-Portal. Range of validity Getting Started is valid for STEP 7 V13. 1.2 Technical support Technical support Technical support for all IA/DT products can be accessed through the following communication channels: ● Phone: + 49 (0) 911 895 7222 ● E-Mail (mailto:support.automation@siemens.com) ● Internet: Online support request form (http://www.siemens.de/automation/support-request) Technical documentation on the Internet Operating instructions and manuals for SITOP are available in the Internet: Operating instructions/manuals (http://www.siemens.de/sitop/manuals) SITOP power supply homepage General news about our power supplies is available in the Internet at the SITOP home page (http://www.siemens.de/sitop). SITOP UPS1600 under STEP 7 V13 Getting Started, 06/2014 5 Introduction 1.3 Additional documentation 1.3 Additional documentation Further information is available in the following documents: ● UPS1600 and UPS1100 manuals ● IO controller manual ● STEP 7 V13 manual SITOP UPS1600 under STEP 7 V13 6 Getting Started, 06/2014 2 Safety notes WARNING Correct handling of the devices When operating electrical devices, it is inevitable that certain components will carry dangerous voltages. Therefore, failure to handle the units properly can result in death or serious physical injury as well as extensive property damage. Only appropriately qualified personnel may work on or in the vicinity of this equipment. Perfect, safe, and reliable operation of this equipment is dependent on proper transportation, storage, installation and mounting. Before installation or maintenance work can begin, the system's main switch must be switched off and measures taken to prevent it being switched on again. If this instruction is not observed, touching live parts can result in death or serious injury. The relevant DIN/VDE regulations or country-specific specifications (e.g. VDE 0510 Part 2 / EN50272-2) must be observed for the storage, assembly and operation of the lead accumulators. It must be ensured that the battery location is suitably ventilated. Potential ignition sources must be separated by at least 50 cm. SITOP UPS1600 under STEP 7 V13 Getting Started, 06/2014 7 Description 3.1 3 System overview Application The principal tasks that you can perform with the SITOP UPS Management: ● Connecting the uninterruptible SITOP UPS1600 power supply to the IO controller S7 ● Configuring the SITOP UPS1600 uninterruptible power supply ● Protecting a computer or a computer network using the uninterruptible power supply ● Defining the battery maintenance intervals Device integration SITOP UPS Management supports the following devices: ● UPS1600 ● UPS1100 UPS1600 can be used with STEP 7 in TIA Portal as of version 12.0 with service pack 1 (SP1). After the UPS1600 has been saved in the hardware catalog of STEP 7 V13 by installing the hardware support package, it can be integrated into projects, parameterized and diagnosed. Languages German, English. French, Italian, Spanish and Chinese being prepared. SITOP UPS1600 under STEP 7 V13 Getting Started, 06/2014 9
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.