Báo cáo y học: "Ultrasound evaluation of the abductor hallucis muscle: Reliability study"

pdf
Số trang Báo cáo y học: "Ultrasound evaluation of the abductor hallucis muscle: Reliability study" 9 Cỡ tệp Báo cáo y học: "Ultrasound evaluation of the abductor hallucis muscle: Reliability study" 589 KB Lượt tải Báo cáo y học: "Ultrasound evaluation of the abductor hallucis muscle: Reliability study" 0 Lượt đọc Báo cáo y học: "Ultrasound evaluation of the abductor hallucis muscle: Reliability study" 0
Đánh giá Báo cáo y học: "Ultrasound evaluation of the abductor hallucis muscle: Reliability study"
4.1 ( 4 lượt)
Nhấn vào bên dưới để tải tài liệu
Để tải xuống xem đầy đủ hãy nhấn vào bên trên
Chủ đề liên quan

Nội dung

Journal of Foot and Ankle Research BioMed Central Open Access Research Ultrasound evaluation of the abductor hallucis muscle: Reliability study Alyse FM Cameron, Keith Rome and Wayne A Hing* Address: AUT University, School of Rehabilitation & Occupation Studies, Health & Rehabilitation Research Centre, Private Bag 92006, Auckland, 1142, New Zealand Email: Alyse FM Cameron - msn7260@aut.ac.nz; Keith Rome - krome@aut.ac.nz; Wayne A Hing* - wayne.hing@aut.ac.nz * Corresponding author Published: 25 September 2008 Journal of Foot and Ankle Research 2008, 1:12 doi:10.1186/1757-1146-1-12 Received: 29 May 2008 Accepted: 25 September 2008 This article is available from: http://www.jfootankleres.com/content/1/1/12 © 2008 Cameron et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Abstract Background: The Abductor hallucis muscle (AbdH) plays an integral role during gait and is often affected in pathological foot conditions. The aim of this study was to evaluate the within and between-session intra-tester reliability using diagnostic ultrasound of the dorso-plantar thickness, medio-lateral width and cross-sectional area, of the AbdH in asymptomatic adults. Methods: The AbdH muscles of thirty asymptomatic subjects were imaged and then measured using a Philips HD11 Ultrasound machine. Interclass correlation coefficients (ICC) with 95% confidence intervals (CI) were used to calculate both within and between session intra-tester reliability. Results: The within-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.99–0.99); medio-lateral width an ICC: of 0.97 (95% CI: 0.92–0.97) and crosssectional area an ICC of 0.98 (95% CI: 0.98–0.99). Between-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.95 to 0.98); medio-lateral width an ICC of 0.94 (95% CI 0.90 to 0.96) and for cross-sectional area an ICC of 0.79 (95% CI 0.65 to 0.88). Conclusion: Diagnostic ultrasound has the potential to be a reliable tool for evaluating the AbdH muscle in asymptomatic subjects. Subsequent studies may be conducted to provide a better understanding of the AbdH function in foot and ankle pathologies. Background The intrinsic muscles of the foot work as a functional unit in order to dynamically stabilise and assist in the support of the medial longitudinal arch [1-3]. The abductor hallucis muscle (AbdH) is the most medial muscle in the first layer of intrinsic muscles of the plantar surface of the foot. The proximal attachment is from the medial process of the calcaneus tuberosity, and its distal attachment is the proximal phalanx with or without attachment onto the medial sesamoid bone, or with insertion exclusively at the medial sesamoid bone [4]. As the tendon lies beneath the transverse axis of the first metatarsal, AbdH performs abduction and plantar flexion of the first metatarsal phangeal joint [5], being active in the late stance and toe-off phases of gait [6], and is a dynamic stabiliser of the longitudinal arch [7]. Musculoskeletal conditions such as hallux valgus (commonly known as a bunion) and pes planus can result in the structure and function of AbdH being adversely affected [5,8]. Page 1 of 9 (page number not for citation purposes) Journal of Foot and Ankle Research 2008, 1:12 An observation commonly seen in patients with diabetes is atrophy of the intrinsic foot muscles, including AbdH, secondary to peripheral motor neuropathy [9]. Atrophy of the intrinsic foot muscle, which is a close representative of the level of motor dysfunction, is understood to result in an imbalance and altered arrangement, thereby causing prominent metatarsal heads, clawing of the toes, and the development of pressure areas predisposing to possible foot ulceration [9,10]. Alternatively, previous studies have also suggested that the muscle's anatomical line is altered and the strength of the muscle is compromised, consequently affecting the biomechanics of gait, the medial longitudinal arch configuration, and degenerative pes planus [5,8-11]. In hallux valgus the AbdH muscle is at a mechanical disadvantage as the distance between the proximal and distal attachments is increased, resulting in the muscle losing its abduction force [8,12]. An imbalance between the muscles of AbdH and Adductor hallucis muscle, which are responsible for coordinating the first metatarsophalangeal joint movements, is also evident, possibly leading to joint deformity [13]. These effects have been demonstrated to increase the load on the posterior tibial muscle, further increasing the likelihood of dysfunction [13]. There are a number of non-invasive techniques to image soft tissue structures. These include magnetic resonance imaging (MRI), computerized tomography (CT), and ultrasound (US), although not all are feasible or practical to operate in the clinical environment. Electromyography (EMG) has also been utilised to measure skeletal muscle activity [14]. Current evidence suggests a good correlation between ultrasound imaging and the "gold standard" of MRI and CT [15]. Furthermore, muscle imaging techniques such as MRI and US have been shown to be of value in inflammatory myopathies [15]. Ultrasound imaging is safe, non-invasive, easily performed and is a considerably less expensive process to undertake, all making it an advantageous piece of clinical equipment [16]. Ultrasonography has also already been shown to be a valid and reliable tool diagnostically in the imaging of skeletal muscle, producing quantitative and qualitative information about muscle architecture [17]. Ultrasound imaging has previously been used for measuring and analysing muscle cross-sectional area of vastus lateralis [18], lumber multifidus [19], and a range of intrinsic foot muscles that includes extensor digitorum brevis, the first interosseus dorsalis muscle, adductor hallucis and the first lumbrical muscle [11]. Ultrasound imaging has previously been used on the foot to measure plantar fascia band thickness in symptomatic and asymptomatic feet and to establish a plantar fasica index [20]. Methodologically, previous studies have used anatomical http://www.jfootankleres.com/content/1/1/12 landmarks as reference points for the perpendicular position of the transducer in relation to the long axis of the limb, in a set repeatable patient position for carrying out the imaging of the identified muscle [11,19-21]. Quantitative analyses of the intrinsic foot muscles, including AbdH, have predominantly been performed on cadaveric feet through dissection [2,22]; however, to date there appears to be no studies that have measured AbdH in the asymptomatic population using ultrasonography. This may be beneficial for the diagnosis of pathology, monitoring adaptations, and providing evidence for the effectiveness of non-surgical interventions in relation to the AbdH muscle. The aim of this study was to evaluate intra-tester within and between-session reliability using diagnostic ultrasound imaging of the AbdH dorso-plantar thickness, medio-lateral width and cross-sectional area. Methods Subjects A convenience sample of thirty subjects were recruited from the University population. Subjects were included if they reported no history of inflammatory arthritis, previous foot or ankle surgery, diabetes, lower limb amputation, or severe hallux valgus as defined by the Manchester Scale [23]. All subjects provided written informed consent. The procedures used in this study were approved by the Universities Ethics Committee. Equipment A Philips HD11 Ultrasound machine linear probe (L12-5 MHz, 50 mm broadband linear array) was used to scan images of the AbdH muscle. An Aquaflex® Ultrasound Gel Pad (Fairfield, USA) was applied directly on the skin superficial to the AbdH muscle for optimal transducer contact and signal penetration. A stable platform held the foot in neutral position at zero degrees. Philips Q-lab Software (Release 5.0) was employed for data quantification. Experimental procedure Subjects were laid in a supine position. The heel and plantar aspect, excluding the first metatarsal, of the involved foot rested against a stable platform designed to fix the ankle in a zero degree neutral position. The posterior aspect of the knee was supported in approximately 15 degrees flexion. The uninvolved leg was also supported. The researcher (AC) palpated the bony anatomical landmark of the anterior aspect of the medial malleolus and a perpendicular scanning line was drawn directly inferiorly. The ultrasound gel pad was applied onto the AbdH muscle belly, inferior to the medial malleolus. Scanning occurred with the transducer applied at a perpendicular angle to the aforementioned scanning line and long axis Page 2 of 9 (page number not for citation purposes) Journal of Foot and Ankle Research 2008, 1:12 of the foot on the proximal aspect of the reference line to encompass the muscle fibres of AbdH. Minimal pressure was applied with the transducer to reduce any possible alterations to the muscle architecture (Figure 1). Using digital callipers, the dorso-plantar thickness and medial-lateral width of the AbdH was measured from the echogenic tissue interface between the muscle belly and the muscle fascia (Figure 2). The cross-sectional area measurement of the AbdH muscle was obtained through manual tracing of the muscle borders using the Philips Qlab Software digital trace with edged detection capabilities (Figure 3). The left and right foot AbdH muscle were scanned for digital investigation, and three separate repetitions of each foot were recorded in order to attain a mean measurement http://www.jfootankleres.com/content/1/1/12 for each subject. The paired data was collapsed into a single measure by taking the mean of the left and right feet. The probe was reset in its holding port between each scan. This entire process was then repeated three to seven days later to gain between day test results. All ultrasonic imaging measurements were undertaken by AC who was a novice researcher but with training using US imaging over 3months in a musculoskeletal paper run at the university. Additional training in scanning was undertaken prior to data collection by an experienced radiologist and sonographer based from the clinical scanning unit at the University Scanning Unit. In addition, one-to-one training sessions were undertaken with an experienced researcher in musculoskeletal US, Analysis was undertaken retrospectively and at the time of scanning to ensure blinding of the results. All images of the AbdH muscle captured were stored on the hard drive for later analysis. Gel Pad Skin AbdH Figure 1 image of abductor hallucis muscle Ultrasound Ultrasound image of abductor hallucis muscle. Page 3 of 9 (page number not for citation purposes) Journal of Foot and Ankle Research 2008, 1:12 http://www.jfootankleres.com/content/1/1/12 Dorso-plantar thickness Medio-lateral width Figure Abductor 2 hallucis muscle with dorso-plantar thickness and medio-lateral width points marked Abductor hallucis muscle with dorso-plantar thickness and medio-lateral width points marked. Data analysis The baseline descriptive information from each subject was obtained. An analysis of the reliability of muscle cross-sectional area, medio-lateral width and dorsalplantar thickness was conducted out using SPSS (version 15, SPSS Inc., Chicago, IL) Repeated measures (test-retest) reliability analyses utilised interclass correlation coefficients (ICC, 3.1) and 95% confidence intervals were obtained. As with other reliability coefficients, there is no standard acceptable level of reliability using the ICC [24]. It is stated that any measure should have an ICC of at least 0.6 to be useful [25]. Bland-Altman plots have been used to provide graphical representation of some of the key reliability findings [26,27]. The Bland-Altman method calculates the range within which the difference between the two occasions will lie with a probability of 95% [26,27]. weight of 68.8 ± 12.35 Kg, and a mean height of 1.71 ± 0.97 m. Descriptive information of the AbdH muscle medio-lateral width, dorso-plantar thickness and crosssectional area are presented in Table 1. With respect to within-session reliability the results demonstrated high reliability for all three parameters measured (Table 2). Based on an average of the three repetitions, between-session reliability (Table 3) showed high agreement of measuring the dorso-plantar thickness of AbdH (ICC: 0.97; 95% CI: 0.95 to 0.98). High reliability was evident for medio-lateral width measurements (ICC: 0.94; 95% CI 0.90 to 0.96). Cross-sectional area of the AbdH was deemed as acceptable (ICC 0.79; 95% CI 0.65 to 0.88). Figure 4 illustrates the Bland & Altman plot between Session 1 and Session 2 for AbdH medio-lateral width, with a 95% limits of agreement, bias of -0.05, with SD of bias of 1.27 (Lower limit -2.54, Upper limit 2.44). Results Thirty subjects (20 female and 10 male) completed the study with a mean age of 28.24 ± 10.15 years, mean Figure 5 illustrates the Bland & Altman plot between Session 1 and Session 2 for AbdH dorso-plantar thickness, Page 4 of 9 (page number not for citation purposes) Journal of Foot and Ankle Research 2008, 1:12 http://www.jfootankleres.com/content/1/1/12 Circumference traced for crosssectional area measurement Figure 3 hallucis muscle with cross-sectional area outlined Abductor Abductor hallucis muscle with cross-sectional area outlined. displaying a 95% limits of agreement, bias of -0.024, with SD of bias of 0.35 (Lower limit -0.67, Upper limit 0.72). Figure 6 illustrates the Bland & Altman plot between Session 1 and Session 2 for AbdH cross-sectional area, with a 95% limits of agreement, bias of -7.3, with SD of bias of 28.50 (Lower limit -63.18, Upper limit 48.54). Discussion With any measuring system there needs to be of proven reliability and validity before being applied in a clinical setting, so that clinicians maybe assured of reproducible and meaningful results. Evaluating the reliability of muscle parameters has been in the past difficult. Only with an increase in accessibility to the higher-end US machines and also the development and increase in availability of low-cost musculoskeletal US machines has it been possible to conduct good reliability studies. There is limited research exploring the AbdH muscle characteristics. There are however, previous studies utilising US, which have demonstrated that it is a statistically valid and reliable method for assessing the cross-sectional area of skeletal muscle [11,18]. A study by Reeves et al (2007) [18] observed measuring the cross-sectional area of vastus lateralis using US, comparing results to that of the findings from MRI (Table 4). Also a previous study used US to determine the cross-sectional area of extensor digitorum brevis, which again proved to be a reliable method of measurement (Table 4) [11]. Few studies to date have looked at measuring the muscle parameters of width and Table 1: Descriptive statistics of abductor hallucis muscle parameters. Parameter Day Mean ± SD ICC (95% CI) Dorso-Plantar Thickness (mm) 1 2 1 2 1 2 11.55 ± 1.09 11.52 ± 1.03 28.98 ± 2.69 29.03 ± 2.54 269.23 ± 35.47 276.55 ± 33.98 0.97 (0.98–0.99) 0.97 (0.98–0.99) 0.97 (0.95–0.98) 0.97 (0.95–0.98) 0.98 (0.96–0.99) 0.95 (0.92–0.97) Medio-lateral Width (mm) Cross-sectional Area (mm2) Page 5 of 9 (page number not for citation purposes) Differences inmedio-lateral width measures (mm) Journal of Foot and Ankle Research 2008, 1:12 http://www.jfootankleres.com/content/1/1/12 5.0 2.5 +1.96 SD 2.44 0.0 Mean -0.1 -1.96 SD -2.54 -2.5 -5.0 24 26 25 27 28 29 30 31 32 33 34 35 36 Average of medio-lateral width measures (mm) Figure 95% Limits 4 of agreement for the measurement of abductor hallucis medio-lateral width (mm) 95% Limits of agreement for the measurement of abductor hallucis medio-lateral width (mm). thickness using US imaging. An earlier study completed a within-session intra-tester and inter-tester reliability study to measure the thickness of multifidus muscle using US, which concluded in a very high inter-rater agreement of the thickness across both assessors (Table 4), therefore indicating that the aforementioned parameters can be measured reliably [19]. The current study's methodology using US was developed based on the protocols of previous work. These included the utilisation of anatomical landmarks as reference points, allowing time for muscle fluid shifts to occur before scanning, the perpendicular transducer angle, and neutral testing position of the ankle [20,26,28]. From a clinical perspective, the role of the AbdH muscle is still yet to be determined but previous work suggests that the AbdH muscle and its distal attachment play an important role in the aetiology as well as in therapy of hallux valgus [5,29,30]. In orthopaedic, plastic and reconstructive surgery the AbdH muscle allows for rising interest as Table 2: Intratester within session reliability ICC values. Parameter Day ICC (95% CI) Dorso-Plantar Thickness (mm) 1 2 1 2 1 2 0.97 (0.98–0.99) 0.97 (0.98–0.99) 0.97 (0.95–0.98) 0.97 (0.95–0.98) 0.98 (0.96–0.99) 0.95 (0.92–0.97) it is taken as a graft for flap-surgery [5]. Hypertrophy of the AbdH muscle have been reported to be an aetiological factor in tarsal tunnel syndrome [31]. Myofascial syndrome of AbdH muscle has been reported to cause heel pain [32] and acupuncture meridians utilising the muscle belly of AbdH muscle has also been reported in the literature [33]. However, the previous studies on evaluating the muscle parameters of the AbdH muscle has been limited by questions related to the reliability, validity, standardisation, methodology, and the ability to detect changes over time. The current study, by assessing the within and between session reliability of image acquisition of the AbdH muscle using a standardised methodology to measure mediolateral width, dorso-plantar thickness and cross-sectional area demonstrated high intra-tester reliability. Limitations to the current study included measurement error in evaluating the cross-sectional area of AbdH through manual digital trace. Future digital/computer generated mapping of the muscle cross-sectional is a possibility; Reeves et al (2004) [18] reported that reducing measurement error could be undertaken by comparing US Table 3: Intratester between-session reliability ICC values. Medio-lateral Width (mm) Cross-sectional Area (mm2) Parameter ICC (95% CI) Dorso-Plantar Thickness (mm) Medio-lateral Width (mm) Cross-sectional Area (mm2) 0.97 (0.95–0.98) 0.94 (0.90–0.96) 0.79 (0.65–0.88) Page 6 of 9 (page number not for citation purposes) Differences in dorso-plantar thickness measure (mm) Journal of Foot and Ankle Research 2008, 1:12 http://www.jfootankleres.com/content/1/1/12 1.5 1.0 +1.96 SD 0.72 0.5 Mean 0.02 0.0 -0.5 -1.96 SD -0.67 -1.0 10 9 11 13 12 14 15 Average of dorso-plantar thickness measures (mm) Differences in cross-sectional area (mm) Figure 95% Limits 5 of agreement for the measurement of dorso-planter thickness (mm) 95% Limits of agreement for the measurement of dorso-planter thickness (mm). 100 +1.96 SD 48.5 50 0 Mean -7.3 -50 -1.96 SD -63.2 -100 200 225 250 275 300 325 350 375 Average of cross-sectional area (mm2) Figure 95% Limits 6 of agreement for the measurement of cross-sectional area (mm2) 95% Limits of agreement for the measurement of cross-sectional area (mm2). Page 7 of 9 (page number not for citation purposes) Journal of Foot and Ankle Research 2008, 1:12 http://www.jfootankleres.com/content/1/1/12 Table 4: Comparison of results gained from other ultrasound studies measuring muscle parameters. Study Parameter Results Severinsen & Andersen (2007) 25 Reeves et al (2004) 21 Wallwork et al (2007) 29 Cross sectional area: extensor digitorum brevis Cross sectional area: vastus lateralis Width: L2–L3 Multifidus Width: L4–L5 Multifidus r = 0.75 ICC = 0.99 ICC = 0.96 ICC = 0.97 cross-sectional results to that taken from an MRI in order to assure the accuracy of the cross-sectional area. However, this is a costly method to adopt in the clinical setting. In the current study, the ultrasonographer was not blinded to the identity of the subjects examined, but randomising the sequence and subjects reduced the potential for bias. Future studies may consider blinding the ultrasonographer to reduce measurement error. Inter-tester reliability was not assessed in the current study but is being planned for future work. A further limitation is the issue of obtaining the spatial relationship of irregular anatomical structure such as the AbdH muscle using 2D sonography. Future work may take into account 3D measurements in conjunction with new technology. Utilising 3D US transducers are planned for future research using the Philips U22 which has 3/4D capabilities. Previous work on multifidus reported on the muscle activity using EMG simultaneously with measuring and monitoring the muscle with US [34]. Future work could utilise the current standard method in conjunction with EMG to evaluate functional parameters of AbdH muscle in conditions such as hallux valgus and tarsal tunnel syndrome. Conclusion Using US in the current study baseline results have been reported for intra-tester reliability in the measurement of the AbdH muscle. Future studies using the current protocol may give a clearer understanding of the role the AbdH muscle plays in pathological conditions that may impact on the foot and ankle. Competing interests References 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. The authors declare that they have no competing interests. 17. Authors' contributions AC carried out the literature review, piloting, data collection and drafted the manuscript. KR and WH participated in the design of the study, statistical analysis and drafting of the manuscript. All authors read and approved the final manuscript. 18. 19. 20. Acknowledgements Foot Science International Ltd (Christchurch, New Zealand) for their support in this research project. 21. Fiolkowski P, Brunt D, Bishop M, Woo R, Horodyski M: Intrinsic pedal musculature support of the medial longitudinal arch: an electromyography study. J Foot Ankle Surg 2003, 42(6):327-33. Kura H, Luo ZP, Kitaoka HB, An KN: Quantitative analysis of the intrinsic muscles of the foot. Anat Rec 1997, 249(1):143-51. Mann R, Inman VT: Phasic activity of intrinsic muscles of the foot. J Bone Joint Surg Am 1964, 46:469-81. Drake RL, Vogl W, Mitchell AWM, Gray H: Gray's anatomy for students Philadelphia: Elsevier/Churchill Livingstone; 2005. Brenner E: Insertion of the abductor hallucis muscle in feet with and without hallux valgus. Anat Rec 1999, 254(3):429-34. Reeser LA, Susman RL, Stern JT: Electromyographic studies of the human foot: experimental approaches to hominid evolution. Foot Ankle 1983, 3(6):391-407. Wong YS: Influence of the abductor hallucis muscle on the medial arch of the foot: a kinematic and anatomical cadaver study. Foot Ankle Int 2007, 28(5):617-20. Arinci Incel N, Genc H, Erdem HR, Yorgancioglu ZR: Muscle imbalance in hallux valgus: an electromyographic study. American Journal Of Physical Medicine & Rehabilitation/Association Of Academic Physiatrists 2003, 82(5):345-9. Greenman RL, Khaodhiar L, Lima C, Dinh T, Giurini JM, Veves A: Foot small muscle atrophy is present before the detection of clinical neuropathy. Diabetes Care 2005, 28(6):1425-30. Andersen H, Gjerstad MD, Jakobsen J: Atrophy of foot muscles. Diabetes Care 2004, 27(10):2382-5. Severinsen K, Andersen H: Evaluation of atrophy of foot muscles in diabetic neuropathy – a comparative study of nerve conduction studies and ultrasonography. J Clin Neurophysiol 2007, 118(10):2172-5. Jahss M: Disorders of the hallux and the first ray. Disorders of the Foot and Ankle 1992, 2:943-72. Incel A, Genc H, Erdem HR, Yorgancioglu ZR: Muscle imbalance in hallux valgus: an electromyographic study. Am J Phys Med Rehabil 2003, 82(5):345-9. Calancie B, Molano MR, Broton JG: Abductor hallucis for monitoring lower-limb recovery after spinal cord injury in man. J Spinal Cord Med 2004, 42(10):573-80. Reimers CD, Finkenstaedt M: Muscle imaging in inflammatory myopathies. Curr Opin Rheumatol 1997, 9:475-85. Bemben MG: Use of diagnostic ultrasound for assessing muscle size. Journal of Strength and Conditioning Research 2002, 16(1):103-8. Perkin HM, Bond EA, Thompson J, Woods EC, Smith C: Realtime ultrasound: an objective measure of skeletal muscle. Physical Therapy Reviews 2003, 8:99-108. Reeves ND, Maganaris CN, Narici MV: Ultrasonographic assessment of human skeletal muscle size. Eur J Appl Physiol 2004, 91(1):116-8. Wallwork TL, Hides JA, Stanton WR: Intrarater and interrater reliability of assessment of lumbar multifidus muscle thickness using rehabilitative ultrasound imaging. J Orthop Sports Phys Ther 2007, 37(10):608-12. Vohra PK, Kincaid BR, Japour CJ, Sobel E: Ultrasonographic evaluation of plantar fascia bands. A retrospective study of 211 symptomatic feet. J Am Podiatr Med Assoc 2002, 92(8):444-9. Huang Y-C, Wang L-Y, Wang H-C, Chang K-L, Leong C-P: The relationship between the flexible flatfoot and plantar fasciitis: ultrasonographic evaluation. Chang Gung Medical Journal 2004, 27(6):443-8. Page 8 of 9 (page number not for citation purposes) Journal of Foot and Ankle Research 2008, 1:12 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. http://www.jfootankleres.com/content/1/1/12 Sarrafian SK, Topouzian LK: Anatomy and physiology of the extensor apparatus of the toes. J Bone Joint Surg Am 1969, 51(4):669-79. Garrow AP, Papgeorgiou A, Silman AJ, Thomas E, Jayson MIV, Macfarlane GJ: The grading of the hallux valgus, the Manchester Scale. J Am Podiatr Med Assoc 2001, 91(2):74-8. Bruton A, Conway JH, Holgate ST: Reliability: what is it, and how is it measured? Physiotherapy 2000, 86(2):94-5. Rankin G, Stokes M: Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses. Clin Rehabil 1998, 12:197-9. Bland J, Altman D: Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol 2003, 22(1):85-93. Mantha S, Roizen M, Fleisher L, Thisted R, Foss J: Comparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis. Anesth Analg 2000, 90:593-602. Vincent WJ: Statistics in kinesiology Second edition. Leeds: Human Kinetics; 1999. Eustace S, Williamson D, Wilson M, O'Byrne J, Bussolari L, Thomas M, Stephens M, Stack J, Weissman B: Tendon shift in hallux valgus: observations at MR imaging. Skeletal Radiol 1996, 25:519-24. Shima H, Okuda R, Kinoshita M, Yasuda T, Abe M: Hallux valgus with rupture of the abductor hallucis tendon: A report of two cases. Japan Journal of Orthopaedic Surgery & Traumatology 2005, 48:1089-90. Sato T, Matsuzaki A, Arinaga M: Tarsal tunnel syndrome due to contracture of abductor hallucis. a case report. Orthopaedics & Traumatology 2000, 49:560-3. Saggini R, Bellomo RG, Affaitati G, Lapenna D, Giamberardino MA: Sensory and Biomechanical Characterization of Two Painful Syndromes in the Heel. J Pain 2006, 8:215-22. Moncayo M, Rudisch A, Kremser C, Moncayo M: 3D-MRI rendering of the anatomical structures related to acupuncture points of the Dai mai, Yin qiao mai and Yang qiao mai meridians within the context of the WOMED concept of lateral tension: implications for musculoskeletal disease. BMC Musculoskeletal Disorders 2007, 8(33):1-7. Kiesela KB, Uhlb TL, Underwood FB, Rodd DW, Nitza AJ: Measurement of lumbar multifidus muscle contraction with rehabilitative ultrasound imaging. Manual Therapy 2007, 12:161-6. Publish with Bio Med Central and every scientist can read your work free of charge "BioMed Central will be the most significant development for disseminating the results of biomedical researc h in our lifetime." Sir Paul Nurse, Cancer Research UK Your research papers will be: available free of charge to the entire biomedical community peer reviewed and published immediately upon acceptance cited in PubMed and archived on PubMed Central yours — you keep the copyright BioMedcentral Submit your manuscript here: http://www.biomedcentral.com/info/publishing_adv.asp Page 9 of 9 (page number not for citation purposes)
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.